On This Job

A gas fireplace that suddenly leaves soot is telling you something about the burner, the logs or the vent. We clear the ports, brush the pilot hood, take the logs out to clean them and place them back to the layout card, wash the glass and look up the vent for nests, rust or fallen debris. A carbon monoxide reading goes in the visit note, along with anything that needs repair.

Burner ports and pilot hood cleared
Logs lifted out, cleaned, placed back to the card
Glass washed and gasket looked at
Vent searched for nests, rust and debris
CO reading noted at the end of the visit

Why a gas unit gets dirty, and why it matters

A gas fireplace looks like it should stay clean forever. The fuel itself burns fairly clean when the burner is set right, but the unit sits in a living room that sends dust, pet hair and lint toward it all year. Some of that settles on the burner ports and the pilot, and when the ports clog the flame changes shape, turning tall, floppy and orange. A flame like that makes soot, and soot ends up on the logs, on the glass and up the vent. During a wildfire season, fine ash can work its way in through a vent cap on the roof or an outside wall. A pilot hood coated in soot or dust can make the safety sensor misread the flame and shut the gas off, so a dirty unit can also become one that will not stay lit. The cleaning addresses all of that at the source.

Once the valve is closed and the metal has cooled, the front panel comes away and the logs or media are lifted out in the order they sit, a layout we note before touching it. Then we clean the burner and its ports, the pilot assembly and the area under the burner tray. Logs that have heavy soot are brushed outside; ones that have cracked or crumbled get a note, since the log layout is part of how the flame burns cleanly. The glass is cleaned of soot and of the white film that builds up from combustion, and the gasket that seals it is looked over. Then everything goes back in its listed position, the gas is turned on, and we check for leaks at the fittings we disturbed before lighting. The flame should come back blue at the base with yellow tips. If it does not, we look further before we leave.

The vent, the room and what we write down

The vent carries the exhaust out, and it is the part we care most about. On a direct vent unit we look at the termination outside for nests, wasp work, plant growth and damage from heat or ash, and make sure nothing is stacked against it. On a unit that vents up an old masonry chimney, we check the flue is open and the damper clamp is in place. A carbon monoxide reading near the fireplace with the unit running tells us whether exhaust is escaping into the room. If the unit sits in a house that had smoke or ash come in from a fire nearby, we say whether that ash reached the burner compartment, which is useful to an insurer. If we find a cracked glass panel, a vent joint that has separated or a burner that has rusted through, we stop and explain it, and a repair is priced separately.

Most gas fireplace cleanings take about an hour and a half, a little more for units with complex log sets. Around West Covina, Walnut and Glendora the units we see run from older vented log sets in brick fireboxes to modern sealed direct vent boxes, and the visit is the same in principle. You need the unit turned off for a few hours before we arrive so the glass and logs are cool, and the area in front of it clear. The maker's label, often tucked in the control area, tells us which gaskets to bring; read it to us at booking if you can. Use the contact page to arrange it, and mention anything you have noticed: soot on the glass, a smell when it runs, a flame that has changed color, or a pilot that keeps going out.

How Fitzroy Chimney Contractors Handles It

Figures on Paper

Each repair item priced in writing first

Evidence Kept

Photos and stills of what we found

Published Rates

Sweeps and inspections at listed prices

Copies Shared

Reports sent to anyone you name

Other Jobs We Handle

Chimney Sweep

Soot, loose creosote and fire debris brushed and vacuumed out of the flue, with any glazed or heat-split tile written down.

Read more

Chimney Inspection

A Level 1 look, with a clear answer on whether the fire left anything a camera ought to see.

Read more

Chimney Repair

Heat-split tiles, loose brick, failed crowns and warped dampers put right after a fire, with the scope on paper first.

Read more

Fireplace Inspection

Firebox, hearth, damper and the wall around the opening checked for heat damage, scorching and gaps that let embers through.

Read more

Fireplace Repair

Cracked firebrick, open back walls, warped dampers and split hearths rebuilt so the opening can hold a fire again.

Read more

Chimney Level 2 Inspection

Video from smoke chamber to cap for $385, the inspection NFPA 211 points to after a chimney fire, a quake or a sale.

Read more

Chimney Cap Installation

Spark-screened caps fixed to the flue top to keep sparks in and embers out, quoted on site from flue size, metal and crown.

Read more

Chimney Flashing Repair

The roof seal around the chimney replaced where heat, age or old tar patches let water reach the framing.

Read more

Chimney Masonry Repair

Heat-cracked joints, loose courses and flaking brick repaired with mortar suited to the brick, after a fire or hard weather.

Read more

Chimney Rebuilds

Chimneys too damaged by fire, quake or age to patch, taken down to brick that still holds and built back with a new liner.

Read more

Fireplace Cleaning

Soot, ash and smoke film cleared from the firebox, doors and face of the fireplace after a hot fire or a smoke backup.

Read more

Gas Fireplace Repair

Pilots that drop out, valves that stick and ignition that fails traced with a meter and repaired on gas fireplaces.

Read more

Fireplace Remodel

A fireplace face, hearth or mantel rebuilt after smoke or fire damage, planned around safe distances to anything that burns.

Read more

Fireplace Inserts

Sealed gas or wood inserts fitted to the old firebox with a new liner to the top, for owners done with open fires.

Read more

Pellet Stove Repair

Pellet stoves that quit, smoke or run hot repaired at the feed, igniter, fans or board, with the vent checked too.

Read more

Wood Stove Repair

Wood stoves that overfired or leak smoke repaired at the door seal, baffle, firebrick, glass and stovepipe.

Read more

Gas Logs

Vented gas log sets fitted to a firebox that will no longer burn wood, with the line, valve and draft tested.

Read more

Chimney Seismic Retrofit

Brick chimneys weakened by a fire or a past quake braced or partly rebuilt so the upper stack is less likely to fall.

Read more

Chimney Crown Repair

The poured top of the chimney resealed or recast once heat, frost or weather has opened cracks in it.

Read more

Dryer Vent Cleaning

Lint cleared from the dryer duct from end to end, since lint packed in a duct can catch fire.

Read more

Chimney Liner Installation

New stainless liners run through a flue that a chimney fire cracked, so the chimney can carry heat and smoke safely again.

Read more

Chimney Leak Repair

Water at the chimney traced to its source and stopped, $550 to $3,300, often after hose water or a cracked crown.

Read more

Chimney Waterproofing

Water repellent brushed onto brick after repairs, so winter storms do not soak masonry a fire has already weakened.

Read more

Chimney Damper Repair

Dampers warped, seized or burned out by a fire repaired or replaced so the flue opens fully and seals when cold.

Read more

Chimney Chase Cover

Rusted or sagging metal tops on factory-built chimney boxes replaced with a cover cut to fit, so water stays off the framing.

Read more
Call (626) 556-9495