Start With What Happened

On This Job

A pellet stove that ran too hot or smoked into the room may have scorched its own wiring or clogged its vent with ash. We take the stove through a diagnosis cycle, test the feed motor, igniter, fans and safety switches, and clean the ash paths. The vent is opened at each joint and looked over for soot and gaps. You get a list of failed parts and a price before we order them.

Diagnosis cycle run before parts are ordered
Feed motor, igniter and fans tested
Safety switches and wiring looked over
Ash paths and vent joints cleaned
Failed parts listed with a price first

Why a pellet stove shuts itself down

Pellet stoves are built to stop rather than burn badly. A sensor on the body reads the temperature, another watches the draft, and the control board shuts the feed down when either reading is wrong. So a stove that keeps stopping is often doing exactly what it should, and the question is why. The usual causes are simple: ash built up in the burn pot and the passages behind it, a vent pipe partly blocked with fly ash, a combustion fan that has slowed, an igniter that has burned out, or pellets that were damp or dusty. A stove that has overheated, with discolored paint, a smell of hot metal or a high limit switch that has tripped, needs a closer look, since that is the stove protecting itself from a fire. We read error codes, test the motors and sensors and look at the vent before guessing at parts.

The vent deserves its own attention. Pellet stoves push their exhaust out under pressure through a small pipe, and that pipe has to be sealed at every joint. A leak there can put exhaust into the room, which a carbon monoxide alarm should catch but should not have to. Fly ash collects in the bends and on the cap outside, and in a fire season the cap can be clogged with ash from outside as well. If the stove vents into an old masonry chimney, the liner and the connection at the bottom matter just as much. We check the run from the stove to the outside, clean what needs cleaning, and test each joint. If a vent pipe or cap took heat from a fire nearby, we say so and write down what we found.

Parts, pricing and what to tell us

Pellet stove parts are specific to the brand and model, and prices vary widely, so there is no single list price for a repair. After testing, you get a written figure for the part and the labor before we order. Common parts are the igniter, the combustion and room fans, the feed motor, the vacuum and temperature switches, the control board and the door and hopper gaskets. Many stoves also need a deep cleaning of the heat exchanger and the passages behind the firebox, which is often enough on its own to get a stalled stove running again. If a stove is old enough that parts are no longer available, we tell you and talk through the options rather than patching it with a part that will not last. A cleaned and tuned older stove can still run well; a cracked firepot or a burned-out exhaust housing usually means the end.

To book, look for the label on the back or under the hopper lid and pass on what it says. Then describe the failure: does the auger drop pellets, does a flame appear, how many minutes pass before it quits, and what the display shows. A note on the pellet brand you burn helps as well, since ash content varies a lot between bags. If the stove overheated or produced smoke in the room, leave it off until we arrive. Owners in West Covina, Glendora and Walnut book this on the same terms. Use the contact page to arrange a time, and keep the hopper empty if the stove smoked. If the stove is one of several things that need attention after a fire, such as a chimney or a fireplace in another room, mention them all and we will look at everything in one visit.

How Fitzroy Chimney Contractors Handles It

Figures on Paper

Each repair item priced in writing first

Evidence Kept

Photos and stills of what we found

Published Rates

Sweeps and inspections at listed prices

Copies Shared

Reports sent to anyone you name

Other Jobs We Handle

Chimney Sweep

Soot, loose creosote and fire debris brushed and vacuumed out of the flue, with any glazed or heat-split tile written down.

Read more

Chimney Inspection

A Level 1 look, with a clear answer on whether the fire left anything a camera ought to see.

Read more

Chimney Repair

Heat-split tiles, loose brick, failed crowns and warped dampers put right after a fire, with the scope on paper first.

Read more

Fireplace Inspection

Firebox, hearth, damper and the wall around the opening checked for heat damage, scorching and gaps that let embers through.

Read more

Fireplace Repair

Cracked firebrick, open back walls, warped dampers and split hearths rebuilt so the opening can hold a fire again.

Read more

Chimney Level 2 Inspection

Video from smoke chamber to cap for $385, the inspection NFPA 211 points to after a chimney fire, a quake or a sale.

Read more

Chimney Cap Installation

Spark-screened caps fixed to the flue top to keep sparks in and embers out, quoted on site from flue size, metal and crown.

Read more

Chimney Flashing Repair

The roof seal around the chimney replaced where heat, age or old tar patches let water reach the framing.

Read more

Chimney Masonry Repair

Heat-cracked joints, loose courses and flaking brick repaired with mortar suited to the brick, after a fire or hard weather.

Read more

Chimney Rebuilds

Chimneys too damaged by fire, quake or age to patch, taken down to brick that still holds and built back with a new liner.

Read more

Fireplace Cleaning

Soot, ash and smoke film cleared from the firebox, doors and face of the fireplace after a hot fire or a smoke backup.

Read more

Gas Fireplace Cleaning

Gas burners, logs and glass cleaned, and the vent checked for the soot or debris that a smoky, yellow flame points to.

Read more

Gas Fireplace Repair

Pilots that drop out, valves that stick and ignition that fails traced with a meter and repaired on gas fireplaces.

Read more

Fireplace Remodel

A fireplace face, hearth or mantel rebuilt after smoke or fire damage, planned around safe distances to anything that burns.

Read more

Fireplace Inserts

Sealed gas or wood inserts fitted to the old firebox with a new liner to the top, for owners done with open fires.

Read more

Wood Stove Repair

Wood stoves that overfired or leak smoke repaired at the door seal, baffle, firebrick, glass and stovepipe.

Read more

Gas Logs

Vented gas log sets fitted to a firebox that will no longer burn wood, with the line, valve and draft tested.

Read more

Chimney Seismic Retrofit

Brick chimneys weakened by a fire or a past quake braced or partly rebuilt so the upper stack is less likely to fall.

Read more

Chimney Crown Repair

The poured top of the chimney resealed or recast once heat, frost or weather has opened cracks in it.

Read more

Dryer Vent Cleaning

Lint cleared from the dryer duct from end to end, since lint packed in a duct can catch fire.

Read more

Chimney Liner Installation

New stainless liners run through a flue that a chimney fire cracked, so the chimney can carry heat and smoke safely again.

Read more

Chimney Leak Repair

Water at the chimney traced to its source and stopped, $550 to $3,300, often after hose water or a cracked crown.

Read more

Chimney Waterproofing

Water repellent brushed onto brick after repairs, so winter storms do not soak masonry a fire has already weakened.

Read more

Chimney Damper Repair

Dampers warped, seized or burned out by a fire repaired or replaced so the flue opens fully and seals when cold.

Read more

Chimney Chase Cover

Rusted or sagging metal tops on factory-built chimney boxes replaced with a cover cut to fit, so water stays off the framing.

Read more